Cart

Added to cart

Go to cart

Your order qualifies for free 2-day shipping and easy returns

High-Performance Handheld Infrared Camera

FLIR T865 (Science)

Model: T865 14° (Science) Go to Product Support
product image

The FLIR T865 infrared camera provides ultimate flexibility and portability for research and science applications, allowing you to collect meaningful thermal data whether the camera is handheld or mounted. With high-performance features including temperature measurements down to -40°C and accuracy as good as ±1°C / ±1%, you'll get reliable temperature measurements every time. FLIR UltraMax® and MSX® (Multi-spectral Dynamic Imaging) provide exceptional image quality and measurement capabilities. The optional Macro Mode allows you to quickly switch from wide angle to close-up analysis without changing the lens. Robust on-board analysis and the ability to record fully radiometric movie files to a removable SD card allow users to save thermal data in nearly any environment, or expand your data analysis capabilities with powerful FLIR Research Studio software. With a streamlined, intuitive user interface and unique feature set, users at all levels can effortlessly record and evaluate thermal data from multiple FLIR cameras and recorded sources simultaneously.

Sales Contact Contact Sales
  • Superior Measurement Capabilities

    Accurately measure a wide range of temperatures and maximize the number of pixels on targets regardless of size or distance from the camera.

  • Ultimate flexibility and portability

    Collect meaningful thermal data in nearly any situation with flexible connectivity - whether the camera is handheld or mounted.

  • Save Time and Effort

    Eliminate the need for complex test set-ups when performing thermal analysis and start testing sooner.

Contact Sales

Want more information on this product?

Call +1 (866) 477-3687 to speak with a knowledgeable specialist.

Specifications
IR Resolution
640 × 480 pixels
Spectral Range
7.5 - 14.0 µm
f-number
1.5
Thermal Sensitivity/NETD
<50 mK at 30°C (14° lens)
Focus
Continuous with laser distance meter (LDM), one-shot LDM, one-shot contrast, manual
Imaging & Optical
Color Palettes
Iron, Rainbow, Rainbow HC, White hot, Black hot, Arctic, Lava
Detector Type and Pitch
Uncooled microbolometer, 12 µm
Digital Camera
5 MP, with built-in LED photo/video lamp
Digital Zoom
1-8x continuous
f-number
1.5
Focus
Continuous with laser distance meter (LDM), one-shot LDM, one-shot contrast, manual
Image Frequency
30 Hz
IR Resolution
640 × 480 pixels
Lens Identification
Automatic
Minimum Focus Distance
1.0 m
Non-radiometric IR video streaming
H.264 or MPEG-4 over Wi-Fi MJPEG over UVC or Wi-Fi
Picture-in-Picture
Resizable and movable
Radiometric IR video recording
Real-time radiometric recording (.csq)
Radiometric IR video streaming
Yes, over UVC
Spectral Range
7.5 - 14.0 µm
Thermal Sensitivity/NETD
<50 mK at 30°C (14° lens)
UltraMax
Quadruples pixel count; activated in menu and processed in FLIR reporting software.
Viewfinder
Yes
Measurement & Analysis
Accuracy
±1°C (±1.8°F): 5 to 100°C (41 to 212°F), ±1%: 100 to 120°C (212 to 248°F), ±2°C (±3.6°F): –40 to 100°C (–40 to 212°F), ±2%: 100 to 650°C (212 to 1202°F), 300 to 2000°C (572 to 3632°F)
Measurement Presets
No measurement, center spot, hot spot, cold spot, User Preset 1, User Preset 2
Object Temperature Range
-40°C to 120°C (-40°F to 248°F); 0°C to 650°C (32°F to 1202°F) 300°C to 2000°C (572°F to 3632°F)
Spot Meter
10 ea. in live mode
Communication & Data Storage
Image File Format
Standard JPEG with measurement data included
Image Storage Mode
Infrared, visual, MSX®, Picture-in-Picture
METERLiNK
Yes
Storage Media
Removable SD card
Time Lapse
10 sec to 24 hrs
Video Out
DisplayPort over USB Type-C
General
Laser Pointer
Yes
Packaging
Infrared camera with lens, small viewfinder eyecup, 2 batteries, battery charger, hard transport case, lanyards, front lens cap, power supplies, printed documentation, SD card (8 GB), cables (USB 2.0 A to USB Type-C, USB Type-C to HDMI, USB Type-C to USB Type-C)
User Interface
Display
4", 640 × 480 pixel touchscreen LCD with auto-rotation
Text
Predefined list or touchscreen keyboard
Voice
60 sec. recording added to still images or video via built-in mic (has speaker) or via Bluetooth
Power
Battery operating time
Approx. 4 hours at 25°C (77°F) ambient temperature and typical use
Battery type
Li-ion battery, charged in camera or on separate charger
Environmental & Certifications
Operating Temperature Range
-15°C to 50°C (5°F to 122°F)
Safety
EN/UL/CSA/PSE 60950-1
Storage Temperature Range
-40°C to 70°C (-40°F to 158°F)
Media gallery
Related Documents
Export Restrictions

Export Restrictions

The information contained in this page pertains to products that may be subject to the International Traffic in Arms Regulations (ITAR) (22 C.F.R. Sections 120-130) or the Export Administration Regulations (EAR) (15 C.F.R. Sections 730-774) depending upon specifications for the final product; jurisdiction and classification will be provided upon request.

FLIR T865 (Science) - Model: T865 14° (Science)